Features
- Evaluates Performance of Lost Circulation Materials under HPHT Conditions
- Various Width Slots for use in Determining Bridging Characteristics under Pre-defined Differential Pressures
- Slurry is stirred at 150 rpm using an Impeller during Heating and Pressurization
- Operating Temperature up to 400°F (204°C)
- Operating Pressure up to 2,000 psi (13.8 MPa)
Regulatory
Designed to meet ASME, CE/PED and NRTL Certifications
Sample Environment
Maximum Temperature: 400°F / 204°C
Maximum Pressure: 2,000 psi / 13.8 MPa
Pressure Vessel
Elastomer seals with backup rings (FKM)
Vessel material: 316SS
Vessel rotation with latching features
LVDT-based filtrate volume measurement
Slot widths: 3.00, 2.00, 1.50, 1.00, 0.50mm (other widths available)
Vessel volume: 860 mL
Dual pressure relief valves
Safety pressure ports
Sample Characteristics
Slurries containing lost circulation materials
Motor System
Magnetic coupling to impeller shaft
Paddle speed: 150 RPM (adjustable)
Temperature Control
PID controller for sample temperature
Wall temperature measurement
Vessel cooling jacket
Redundant latching over-temperature circuit
Temperature control accuracy: ±2°F / ±1°C
Pressure Control
PID controller and regulator for automatic sample pressure
Manual regulator for filtrate back-pressure control
Pressure control accuracy: ±10 psi of F.S.
Pressurizing Media
Nitrogen
Data Acquisition and Control System
Chandler Engineering 5270 software, calibration features
Ethernet interface
Utilities
Power: 208-230 VAC, ±10%, 50/60 Hz