Skip to content
   

3530 Viscometer

A Critical tool for Completion, Cementing and Drilling Fluids
The 3530 is a fully automated concentric cylinder viscometer designed to meet API and ISO requirements for viscosity measurements of many of the fluids used in well servicing. This viscometer is fully operational in manual mode without the use of a computer or as a computer controlled viscometer with preconfigured periodic shear rate ramping. The Rheo 3000 Data Acquisition Software is provided with the instrument and provides a powerful tool ensuring consistent testing parameters and results.

Operational Simplicity
The 3530 is an automated viscometer combined with our powerful Rheo 3000 Data Acquisition Software running on your computer (Software is an optional/additional feature). This combination provides complete, programmable control of the viscometer's speed throughout a test cycle including step changes, linear ramps and constant speeds as low as 0.01 rpm. Rheo 3000 also provides automatic data acquisition graphical display and analysis of the test results. All test data is stored in a spreadsheet compatible file format for ease of data handling.
  • Specifications +


    Features
    • Easy to Set-up, Operate, Clean and Maintain
    • Rheo 3000 Data Acquisition Software
    • Automatic Calculation of Power Law, Bingham Plastic and Herschel-Bulkley Parameters
    • Remote Control of Motor System (Step Changes, Linear Ramps, Constant Speed)
    • Automatic Calibration Capability
    • Meets API and ISO Standards for Oilfield Cements and Completion Fluids
    • Multiple Rotor / Bob Combinations and Spring Factors Available
    • Optional Thermal Cup

    Operating Conditions
    41°F - 104°F / 5°C - 40°C
    Voltage Rating
    100 - 240 VAC
    Current Rating
    2 Amps
    Frequency Rating
    50/60 Hz
    Voltage Fluctuations
    120 VAC ± 5%; 220 VAC ± 5%

    Environmental (Indoor use only)
    120 VAC ± 5%; 220 VAC ± 5%
    Pollution Degree: 2
    Installation: Category II
    Altitude: 2000m
    Humidity: 10 – 80% non-condensing
    Shear Rate Accuracy 
    ±0.01 rpm
    Torque Accuracy 
    ±0.5 dial reading from 1 to 260 degrees
    Operating Speeds
    0.01 to 1000 rpm when PC controlled

    Utilities
    Power Requirements
    120 or 240 Volts, 50/60 Hz, 700 W
    Physical Dimensions (w x d x h)
    7 x 12 x 18.2 in. / 18 x 31 x 46 cm
    Instrument Weight
    17 lb / 7 kg
    Shipping Weight
    50 lb / 23 kg
    Sample Container Volume
    350mL