Skip to content
   

3330 In-Line Viscometer

Model 3330 In-Line Viscometer

A Critical Tool for Stimulation Fluids
The 3330 In-Line Viscometer provides continuous, real-time viscosity and temperature measurements for a wide range of oilfield fluids, including fracturing fluids, drilling muds and cement slurries. Built for durability, it is engineered to perform reliability in the harsh and demanding environments encountered during well servicing and drilling operations. 



Utilizing API-compliant Couette Rotor and Bob (R1-BI) geometry, the 3330 operates at a fixed shear rate of 511 secˉ¹, delivering accurate and consistent data. Viscosity readings are transmitted via 4-20 mA signal loops to the Control Treatment Monitoring Vehicle, with a digital readout conveniently located on the front panel for local monitoring. 
 
Operational Simplicity
Designed for integration on the low-pressure side of the blender, the 3330 draws a slipstream sample from the hydration tank or fluid system. It is easy to operate, quick to disassemble for cleaning, and features replaceable components to minimize downtime. An optional pH probe is available for expanded fluid monitoring capabilities.

Whether used for fracturing, drilling, or cementing, the 3330 delivers critical viscosity data to support wellbore integrity, zonal isolation, cuttings transport and fluid performance optimization.

A ruggedized, field-ready counterpart to the 3500 series benchtop viscometer, the 3330 is purpose-built for real-world analysis of oilfield fluids across all phases of drilling, completion, stimulation and cementing operations.


  • Specifications +


    Features
    • Continuous, Real Time, Viscosity and Temperature Measurement
    • Easy to Set-Up, Operate, Clean, Maintain and Calibrate
    • API-Compliant Couette Rotor and Bob (R1-B1) Geometry 
    • Fixed Shear Rate of 511 sec-¹
    • 4–20 mA Signal Loops for Data Transmission
    • Digital Readout on Front Panel
    • Optional pH probe for Expanded Fluid Monitoring Capabilities

    Shear Rate: 511 sec-1
    Measurement Accuracy: ±2.0 cP
    Sample Temperature: Ambient
    Sample Volume: 250mL
    Operating Conditions: 50°F - 140°F (10°C - 60°C)
    Rotor: R1
    Bob: B1
    Spring: F1
    **Additional Bob Size and Spring Factor Combinations Available

    Options
    3330-01:
    Transport Case
    3330-02: pH Measurement
    P-2838: 100cP Calibration Fluid

    Utilities
    Power Requirements: 
    Model | Power Requirements
    3330-DC | 12 VDC 6A
    3330-DC | 120/240 VAC 2A

    Dimensions (wxdxh): 17 x 15 x 20 in. / 43 x 38 x 51 cm

  • Articles +

  • Brochures +

  • Manuals +

  • Standards +


    API R1-B1 geometry